  1. Application:

It’s a applicable to incubate, fermentation, hybridization and biochemical reactions and the enzyme, cells, microorganisms and Agricultural Sciences for the bacteria in medical, biology, environment laboratory and scientific research institutes.

  • Technical data:

Model

SM-150B SM-250B
Mains voltage 220V, 50Hz
Temperature range 5—50℃
Power consumption 800W 900W
Dimension of the shaking platform 370×370mm×2 440×440×2
Shaking frequency 30—280±5RPM/min

Shaking movement range

Φ28mm
  1. Structure:
  2. Shaking incubator for the appearance of vertical, body and the outer door of using quality plate, the surface spray. Use within 6mm toughened glass door. With large observation window boxes do not have to open the door that is clearly observed inside the training materials Workshop bright stainless steel plates, oscillating platform placed in the bottom of studios, with different specifications 1.30-flask arbitrary folder can be chosen. (Note: flask folder, spring-may accordance customized user needs.) Shake frequency no step adjustable oscillation stable, low noise. Between studios and toughened glass with silicone rubber gasket to ensure that within the sealed doors and studios. Low temperature circulatory system by the fan, electric heaters, refrigeration evaporators I. Wind board composition, winds Road reasonable structure, ensure uniform indoor temperature, workshops and box uses hard PVC foam board insulation technology.
  3. Refrigeration equipment configuration delay start, high pressure, flow multiple protection. Refrigeration for forced convection, with the use of safe and stable operation, a quiet fan design, or cooling of such characteristics.
  4. Shake frequency control use professional microcomputer adjust, which is soft start, fast dynamic response, timing and so on.

4. The microprocessor intelligent temperature controller is working with self-adjust PID method. It is of higher accuracy and rapid controlling, comparing to normal PID controlling method. The set value of the temperature and the actual temperature were all digitally displayed. Upper limit of the temperature as alarm function was included as standard function. Give an alarm and cut off the heater power at the same time, use the touch keystroke setting, revise the parameter and have digital timers

Description

  1. Application:

It’s a applicable to incubate, fermentation, hybridization and biochemical reactions and the enzyme, cells, microorganisms and Agricultural Sciences for the bacteria in medical, biology, environment laboratory and scientific research institutes.

  • Technical data:

Model

SM-150B SM-250B
Mains voltage 220V, 50Hz
Temperature range 5—50℃
Power consumption 800W 900W
Dimension of the shaking platform 370×370mm×2 440×440×2
Shaking frequency 30—280±5RPM/min

Shaking movement range

Φ28mm
  1. Structure:
  2. Shaking incubator for the appearance of vertical, body and the outer door of using quality plate, the surface spray. Use within 6mm toughened glass door. With large observation window boxes do not have to open the door that is clearly observed inside the training materials Workshop bright stainless steel plates, oscillating platform placed in the bottom of studios, with different specifications 1.30-flask arbitrary folder can be chosen. (Note: flask folder, spring-may accordance customized user needs.) Shake frequency no step adjustable oscillation stable, low noise. Between studios and toughened glass with silicone rubber gasket to ensure that within the sealed doors and studios. Low temperature circulatory system by the fan, electric heaters, refrigeration evaporators I. Wind board composition, winds Road reasonable structure, ensure uniform indoor temperature, workshops and box uses hard PVC foam board insulation technology.
  3. Refrigeration equipment configuration delay start, high pressure, flow multiple protection. Refrigeration for forced convection, with the use of safe and stable operation, a quiet fan design, or cooling of such characteristics.
  4. Shake frequency control use professional microcomputer adjust, which is soft start, fast dynamic response, timing and so on.

4. The microprocessor intelligent temperature controller is working with self-adjust PID method. It is of higher accuracy and rapid controlling, comparing to normal PID controlling method. The set value of the temperature and the actual temperature were all digitally displayed. Upper limit of the temperature as alarm function was included as standard function. Give an alarm and cut off the heater power at the same time, use the touch keystroke setting, revise the parameter and have digital timers

Reviews

There are no reviews yet.

Be the first to review “RS0141-Shaking-Incubator-with-Temperature-Model-SM-150B”

Your email address will not be published. Required fields are marked *

Welcome to Ricado Sunnies Limited Online Medical Equipment shop We are Sole Representative of Surgifield Medical England in Nigeria and we have large stock of Medical, Laboratory, Hospital, Scientific and Teaching Aids in our Warehouse and Showroom. You can search for products by name for quick access Dismiss