Purpose

It is used for detecting the parameters of RBC, WBC, HGB and differential count.

The analyzer is used for determination of the following 20 parameters and 3 histogram blood specimens in Table 1-1:

Items Abbreviation Units
White blood cell or Leukocyte WBC 103/uL
Lymphocyte LYM# 103/uL
Mid-sized Cell MID# 103/uL
Granulocyte GRAN# 103/uL
Lymphocyte Percentage LYM% %
Mid-sized Cell Percentage MID% %
Granulocyte percentage GRAN% %
Red blood cell or Erythrocyte RBC 106/uL
Hemoglobin concentration HGB g/dL
Hematocrit HCT %
Mean Corpuscular(erythrocyte)cell volume MCV fL
Mean cell hemoglobin MCH pg
Mean cell hemoglobin concentration MCHC g/dL
Red Blood Cell Distribution Width- Standard Deviation RDW-SD fL
Red Blood Cell Distribution Width- Coefficient of Variation RDW-CV %
Platelet PLT 103/uL
Mean Platelet Volume MPV fL
Platelet Distribution Width PDW %
Plateletcrit PCT %
Plateletcrit-large Cell Ratio P-LCR %
White BLood Cell Histogram WBC Histogram
Red Blood Cell Histogram RBC Histogram
Platelet Histogram PLT Histogram

Specifications

  • Standard Classification of the instrument

According to anti-electrical shock hazard: Grade Ⅱ,Pollution 2

According to the defence for deleterious liquid: General Device (Closing device of non-defensive liquid)

According to the recommended disinfection/sterilization method of the manufactory.

Disinfectant device recommended by manufactory

According to safety degree in condition that using gas mixture of flammable anesthetic gas and air or gas mixture of oxygen and nitrous oxide: Do not use the equipment in condition that using gas mixture of oxygen and nitrous oxide

According to working status: continuous running equipment.

  • Principles of Measurement :

Blood cells are counted and sized by electrical impedance method.

Hemoglobin is determined by colorimetry method.

Description

Purpose

It is used for detecting the parameters of RBC, WBC, HGB and differential count.

The analyzer is used for determination of the following 20 parameters and 3 histogram blood specimens in Table 1-1:

Items Abbreviation Units
White blood cell or Leukocyte WBC 103/uL
Lymphocyte LYM# 103/uL
Mid-sized Cell MID# 103/uL
Granulocyte GRAN# 103/uL
Lymphocyte Percentage LYM% %
Mid-sized Cell Percentage MID% %
Granulocyte percentage GRAN% %
Red blood cell or Erythrocyte RBC 106/uL
Hemoglobin concentration HGB g/dL
Hematocrit HCT %
Mean Corpuscular(erythrocyte)cell volume MCV fL
Mean cell hemoglobin MCH pg
Mean cell hemoglobin concentration MCHC g/dL
Red Blood Cell Distribution Width- Standard Deviation RDW-SD fL
Red Blood Cell Distribution Width- Coefficient of Variation RDW-CV %
Platelet PLT 103/uL
Mean Platelet Volume MPV fL
Platelet Distribution Width PDW %
Plateletcrit PCT %
Plateletcrit-large Cell Ratio P-LCR %
White BLood Cell Histogram WBC Histogram  
Red Blood Cell Histogram RBC Histogram  
Platelet Histogram PLT Histogram  

Specifications

  • Standard Classification of the instrument

According to anti-electrical shock hazard: Grade Ⅱ,Pollution 2

According to the defence for deleterious liquid: General Device (Closing device of non-defensive liquid)

According to the recommended disinfection/sterilization method of the manufactory.

Disinfectant device recommended by manufactory

According to safety degree in condition that using gas mixture of flammable anesthetic gas and air or gas mixture of oxygen and nitrous oxide: Do not use the equipment in condition that using gas mixture of oxygen and nitrous oxide

According to working status: continuous running equipment.

  • Principles of Measurement :

Blood cells are counted and sized by electrical impedance method.

Hemoglobin is determined by colorimetry method.

Reviews

There are no reviews yet.

Be the first to review “MODEL SM-9000 Full-Automated Hematology Analyzer”

Your email address will not be published. Required fields are marked *

Welcome to Ricado Sunnies Limited Online Medical Equipment shop We are Sole Representative of Surgifield Medical England in Nigeria and we have large stock of Medical, Laboratory, Hospital, Scientific and Teaching Aids in our Warehouse and Showroom. You can search for products by name for quick access Dismiss