[Main Structure of the Product]

The medical X-ray protective screen (“screen” for short) is composed of flat leads and iron plates.

The screen has three types: single, double and triple.

. [Performance]

The lead equivalent is not less than 0.5mmpb.

. [Application of the Product]

The screen is used for the protection of X-ray photograph room or the dental photograph, bedside photograph and surgical room photograph.

. [Applicability]

For the people work in research of radiation of medical, health, epidemic prevention unit and the people in X-ray room.

. [Usage]

You can choose the screen according to the size of the machine’s room and the need of the protection. The screen is mainly equipped with 6”X8” lead glass watch window, the round side can be sealed by adhesive so as to fix it.

Single screen: 1800mm high, 900mm wide, fixed with 4 castors, the front 2 are directed ones and the rear 2 are steering ones.

Double screen: 1800mm high, 900mm wide, the secondary screen is 400mm wide, fixed with 5 castors, the front 2 in the bottom of the main screen are directed ones and the rear 2 in the bottom of the main screen are steering ones, the secondary screen has 1 steering castor in its bottom.

Triple screen: 1800mm high, 900mm wide, each secondary screen is 400mm wide, fixed with 6 castors, the front 2 in the bottom of the main screen are directed ones and the rear 2 in the bottom of the main screen are steering ones, each of the two secondary screen has 1 steering castor in its bottom.

The castors are used to adjust the front and rear of the screen and to move it easily. The main screen and the secondary screen of the double and triple screens are connected with links.

. [Attention]

The screen should avoid to be bumped, otherwise the X-ray can leak.

. [Storage]

Store it in the room of cooling, the humidity should not more than 80%, no corrosive gas, and well airy.

Description

[Main Structure of the Product]

The medical X-ray protective screen (“screen” for short) is composed of flat leads and iron plates.

The screen has three types: single, double and triple.

. [Performance]

The lead equivalent is not less than 0.5mmpb.

. [Application of the Product]

The screen is used for the protection of X-ray photograph room or the dental photograph, bedside photograph and surgical room photograph.

. [Applicability]

For the people work in research of radiation of medical, health, epidemic prevention unit and the people in X-ray room.

. [Usage]

You can choose the screen according to the size of the machine’s room and the need of the protection. The screen is mainly equipped with 6”X8” lead glass watch window, the round side can be sealed by adhesive so as to fix it.

Single screen: 1800mm high, 900mm wide, fixed with 4 castors, the front 2 are directed ones and the rear 2 are steering ones.

Double screen: 1800mm high, 900mm wide, the secondary screen is 400mm wide, fixed with 5 castors, the front 2 in the bottom of the main screen are directed ones and the rear 2 in the bottom of the main screen are steering ones, the secondary screen has 1 steering castor in its bottom.

Triple screen: 1800mm high, 900mm wide, each secondary screen is 400mm wide, fixed with 6 castors, the front 2 in the bottom of the main screen are directed ones and the rear 2 in the bottom of the main screen are steering ones, each of the two secondary screen has 1 steering castor in its bottom.

The castors are used to adjust the front and rear of the screen and to move it easily. The main screen and the secondary screen of the double and triple screens are connected with links.

. [Attention]

The screen should avoid to be bumped, otherwise the X-ray can leak.

. [Storage]

Store it in the room of cooling, the humidity should not more than 80%, no corrosive gas, and well airy.

Reviews

There are no reviews yet.

Be the first to review “LEAD SCREEN STANDING ( Medical X-ray Protective Screen) MODEL:SM-FA05”

Your email address will not be published. Required fields are marked *

Welcome to Ricado Sunnies Limited Online Medical Equipment shop We are Sole Representative of Surgifield Medical England in Nigeria and we have large stock of Medical, Laboratory, Hospital, Scientific and Teaching Aids in our Warehouse and Showroom. You can search for products by name for quick access Dismiss